Chlorinated solvent contamination (TCE and PCE) impacted groundwater at multiple wells (MW-04, MW-07, MW-44) at depths of 20–30 feet below ground surface at a former manufacturing plant in southern Georgia. Both source area treatment and off-site migration control were required to achieve site remediation objectives.
Large-scale treatment using BAM (14 DPT points, 2,800 gallons) and ABC+ soybean electron donor with zero valent iron (6 DPT points, 1,200 gallons) was applied around MW-04 and MW-07, with 40 injection points per well. A BAM/ABC+ mixture was installed as a barrier wall around MW-44 to intercept and treat migrating contamination.
Three rounds of post-treatment sampling confirmed greater than 99% overall chlorinated solvent reduction site-wide at the former manufacturing plant in southern Georgia. MW-04 reached 95.3% reduction, MW-07 reached 99.9% reduction, and MW-44 reached 99.8% reduction. The combined BAM and ABC+ soybean electron donor with zero valent iron injection program addressed both source area contamination at MW-04 and MW-07 and off-site migration at MW-44, where a barrier wall configuration intercepted and treated migrating TCE and PCE. Treatment was delivered to depths of 20–30 feet below ground surface through 14 BAM DPT points and 6 ABC+ DPT points, with 40 injection points per well at the source area wells.
Superfund ISTR Under Strict Air Emission Limits
Bioremediation for PFAS
High-Profile ISTR of Historic Chemical Disposal Impacts
Explore real-world remediation projects where VIYA’s technology-agnostic approach, field expertise, and integrated treatment strategies have been applied to complex site conditions. Browse case studies by contaminant, technology, industry, and project type to see how tailored solutions translate into measurable results.